Customization: | Available |
---|---|
Customized: | Customized |
Certification: | ISO, CE |
Still deciding? Get samples of US$ 241/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ITV Series electro-pneumatic and electronic vacuum regulators control air/vacuum pressure steplessly in proportion to an electric signal. They are lightweight in design with a bright and easy-to-read LED display. The monitor output is available either as analog output or switch output.
Product FeatureFor the stepless control of vacuum pressure in proportion to electrical signals.
1. Linearity: ±1% F.S. or less
2. Hysteresis: 0.5% F.S. or less
3. Repeatability: ±0.5% F.S. or less
4. High-speed response time: 0.1 s (Without load)
5. High stability - Sensitivity: 0.2% F.S. or less
Model | ITV009_ | |
Min. supply pressure |
Set pressure -1 kPa | |
Max. supply pressure | -101 kPa | |
Set pressure range | -1 to -100 kPa | |
Power supply | Voltage | DC24V±10%, DC12 to 15V |
Current consumption |
Power supply voltage DC24 V type: 0.12 A or less Power supply voltage DC12 to 15 V type: 0.18 A or less |
|
Input signal | Voltage type | DC0 to 5V, DC0 to 10V |
Current type | DC4 to 20mA, DC0 to 20mA (Sink type) | |
Input impedance | Voltage type | Approx. 10 kΩ |
Current type | Approx. 250 kΩ | |
Output signal*2) |
Analog output |
DC1 to 5 V (Output impedance: Approx. 1 kΩ) Output accuracy ±6% F.S. or less |
Linearity | ±1% F.S. or less | |
Hysteresis | 0.5% F.S. or less | |
Repeatability | ±0.5% F.S. or less | |
Sensitivity | 0.2% F.S. or less | |
Temperature characteristics | ±0.12% F.S./ºC or less | |
Working temperature | 0 to 50ºC (No condensation) | |
Enclosure | IP65 equivalent*3) | |
Connection type | Built-in One-touch fittings | |
Connection size | For single unit | Metric size 1, 2, 3: Φ4 |
Inch size 1, 2, 3: Φ5/32" | ||
Manifold | Metric size 1, 3: Φ6, 2: Φ4 | |
Inch size 1, 3: Φ1/4", 2: Φ5/32" | ||
Weight*1) | 100 g or less (Without options) |
*1) Indicates the weight of a single unit
For IITV00-n
Total weight (g) ≤ Stations (n) × 100 + 130 (Weight of end block A, B assembly) + Weight (g) of DIN rail
*2) When measuring ITV analog output from 1 to 5 VDC, if the load impedance is less than 100 kΩ, the analog output monitor accuracy of ±6% F.S. or less may not be available.
The product with an accuracy of within ±6% is supplied upon your request.
Output pressure remains unaffected.
*3) When using under the conditions equivalent to IP65, connect the fitting or tube to the breathing hole before use.
*4) When there is a downstream flow consumption, pressure may become unstable depending on piping conditions.
*5) When the power is turned on, a noise may be generated. This noise is normal and does not indicate a fault.
Ordering Code ITV009 Series Compact Vacuum Regulator
For single unit and single unit for manifold
9→ Pressure range | 9: -100kPa | ||
0→ Supply voltage |
0: DC24V±10%
|
1: DC12 to 15V | |
3→ Input signal | 0 |
Current type DC4 to 20mA (Sink type)
|
|
1 |
Current type DC0 to 20mA (Sink type)
|
||
2 |
Voltage type DC0 to 5V
|
||
3 |
Voltage type DC0 to 10V
|
||
Nil1→ Built-in One-touch fittings type | |||
For single unit
|
Symbol | Nil | U |
Metric size(Light gray) |
Inch size (Orange)
|
||
VAC1 | Φ4 | Φ5/32'' | |
OUT2 | |||
ATM3 | |||
For manifold
|
Symbol | Nil | U |
Metric size(Light gray) | Inch size (Orange) | ||
VAC1 | Φ6 | Φ1/4'' | |
OUT2 | Φ4 | Φ5/32'' | |
ATM3 | Φ6 | Φ1/4'' | |
Nil2→ Base type |
Nil: For single unit
|
M: For manifold
|
|
Nil3→ Bracket (single unit only) | Nil | Without bracket | |
B | Flat bracket | ||
C | L-bracket | ||
N→ Cable connector |
N: Without cable connector
|
S: Straight type 3 m
|
L: Right angle type 2 m
|
02→ Stations | 02: 2 stations |
03: 3 stations | |
... ... | |
10: 10 stations | |
Nil→ One-touch fitting size for supply/exhaust parts (End plate) |
Nil: Φ6 (Light gray)
|
U: Φ1/4" (Orange) | |
n→ Option |
If a DIN rail longer than the specified stations is required, specify the applicable stations in two digits. (Max. 10 stations) Example) IITV00-05-07
|
* A DIN rail with the length specified by the number of stations is attached to the manifold.
For dimensions of the DIN rail, refer to the external dimensions.
VPC Box | White Box | Color Box | VPC Carton | Pallet |
Delivery time:
conventional products | customized products | specially customized products |
on the day of payment | 10 workdays | 25 workdays. |
Payment term:
Paypal | TT | Western Union | DP | LC | Money Gram | Online Bank | Alibaba credit order | Pay later | DA |
YES | YES | YES | NO | NO | YES | YES | YES | YES |
YES |
Transportation:
Express(DHL, UPS, TNT, JCEX, FEDEX) is available.
Sea and Air transports are available.
The most suitable transport way will be chosen for you.
Q1:What is your quality assurance?
A:We will inspect one by one before delivery.If the product is damaged in transit or has quality problems, you can choose to refund or resend the product, and the freight will be borne by us.
Q2:What is your terms of payment?
A: TT ,We'll show you the photos of the products and packages before you pay the balance.
B: Paypal payment, Bank transfer,Alibaba Trade Assurance order also available.
Q3: How about the lead time?
A: Normally it will take 3-7 days for our routine products.
Q4:What is your sample policy?
A: Some free samples can be offered if you contact us.
Q5:How about the warranty?
A: 1 year warranty.