PF2A Series Digital Flow Switch Sensor For Air
Model | PF2A710 | PF2A750 | PF2A711 | PF2A721 | PF2A751 | |
Working medium | Dry Air, Nitrogen | |||||
Rated flow range | 1 to 10L/min | 5 to 50L/min | 10 to 100L/min | 20 to 200L/min | 50 to 500L/min | |
Mininum set unit | 0.1L/min | 0.5L/min | 1L/min | 2L/min | 5L/min | |
Accumulated pulse flow rate exchange value(Pluse width:50ms) | 0.1L/pulse | 0.5L/pulse | 1L/pulse | 2L/pulse | 5L/pulse | |
Display units*1,2) | Instantaneous flow rate | L/min, CFM×10 -2 | L/min, CFM×10 -1 | |||
Accumulated flow | L, ft³×10 -1 | |||||
Working temperature | 0 to 50ºC | |||||
Accuracy*3) | ±5%F.S. | |||||
Repeatability | ±1%F.S. | ±2%F.S. | ||||
Temperature characteristics | ±3%F.S. (15 to 35ºC, 25ºC reference), ±5%F.S. (0 to 50ºC, 25ºC reference) | |||||
Current consumption | 150mA or less | 160mA or less | 170mA or less | |||
Port size(Rc, NPT, G) | 1/8, 1/4 | 3/8 | 1/2 | |||
Detection type | Heater type | |||||
Operating pressure | -50kPa to 0.5MPa | -50kPa to 0.75MPa | ||||
Proof pressure | 1.0MPa | |||||
Accumulated flow range*4) | 0 to 999999L | |||||
Output specifications*5) | Switch output | NPN open collector | Max. load current: 80mA; Internal voltage drop: 1V or less
Max. applied voltage: 30V; 2outputs |
|||
PNP open collector | Max. load current: 80mA;
Internal voltage drop: 1.5V or less; 2outputs |
|||||
Accumulated pulse output | NPN or PNP open collector (same as switch output) | |||||
Status LED's | Lights up when output is turned ON OUT1: Green; OUT2: Red | |||||
Response time | 1 sec. or less | |||||
Hysteresis | Hysteresis mode: Variable (can be set from 0), Window comparator mode : 3-digit fixed | |||||
Power supply voltage | DC12 to 24 V±10% | |||||
Environment | Enclosure | IP65 | ||||
Working temperature | Operating: 0 to 50ºC, Stored: -25 to 85ºC (with no freezing and condensation) | |||||
Withstand voltage | AC 1000V for 1 minute between terminals and housing | |||||
Insulation resistance | 50M or more (DC 500V measured via megohmmeter) between terminals and housing | |||||
Noise resistance | 1000V P-P pulse width1μs lasts 1ns |
*1) For digital flow switch with unit switching function. (Fixed SI unit [(L/min, or L, m³ or m³×10³)] will be set for switch type without the unit switching function.)
*2) Flow rate display can be switched between the basic condition of 0ºC, 101.3 kPa and the standard condition (ANR) of 20ºC, 101.3 kPa, and 65% RH.
*3) The piping on the IN side must have a straight section of piping whose length is 8 times the piping diameter or more. If a straight section of piping is not installed, the accuracy may vary by±5% F.S. or more.
*4) Accumulated flow rate is reset when the power supply turns OFF.
*5) Switch output and accumulated pulse output can be selected during initial setting.
*6) Window comparator mode - Since hysteresis will reach 3 digits, keep P_1 and P_2 or n_1 and n_2 apart by 7 digits or more. (In case of output OUT2, n_1, 2 to be n_3, 4 and P_1, 2 to be P_3, 4.)
*7) For details about wiring and thread type, please contact VPC.
*8) Any products with tiny scratches, smears, or display color variation or brightness which does not affect the performance are verified as conforming products.
Part No. | Min. rated flow rate value | Max. rated flow rate value |
PF2A710 | 1NL/min | 10NL/min |
3.5CFM×10-2 | 35.0CFM×10-2 | |
PF2A750 | 5NL/min | 50NL/min |
18.0CFM×10-2 | 176.0CFM×10-2 | |
PF2A711 | 10NL/min | 100NL/min |
3.5CFM×10-1 | 35.5CFM×10-1 | |
PF2A721 | 20NL/min | 200NL/min |
7.0CFM×10-1 | 71.0CFM×10-1 | |
PF2A751 | 50NL/min | 500NL/min |
18.0CFM×10-1 | 176.0CFM×10-1 |
* When using the analog output of the standard state, please convert according to the following formula.
Base state flow rate value ÷ 0.927 = Standard state flow rate value.
7→ Integrated display type | ||||||||
10→ Flow rate range | 10: 1 to 10L/min | 50: 5 to 50L/min | 11: 10 to 100L/min | |||||
21: 20 to 200L/min | 51: 50 to 500L/min | |||||||
Nil1→ Thread type | Nil: Rc | N: NPT | F: G | |||||
01→ Port size | Symbol | Port size | Flow rate (L/min) | Applicable model | ||||
10 | 50 | 100 | 200 | 500 | ||||
1 | 1/8 | √ | √ | - | - | - | PF2A710/750 | |
2 | 1/4 | √ | √ | - | - | - | ||
3 | 3/8 | - | - | √ | √ | - | PF2A711/721 | |
4 | 1/2 | - | - | - | - | √ | PF2A751 | |
27→ Output specifications | 27: NPN open collector 2outputs | 67: PNP open collector 2outputs | ||||||
Nil2→ Lead wire | Nil: Lead wire withM12 connector (3m) | N: Without lead wire | ||||||
M→ Unit specifications | Nil: With unit switching function | M: Fixed SI unit | * Fixed units:Instantaneous flow rate: L/min Accumulated flow: L |
VPC Box | White Box | Color Box | VPC Carton | Pallet |
Delivery time:
conventional products | customized products | specially customized products |
on the day of payment | 10 workdays | 25 workdays. |
Payment term:
Paypal | TT | Western Union | DP | LC | Money Gram | Online Bank | ****** credit order | Pay later | DA |
YES | YES | YES | NO | NO | YES | YES | YES | YES |
YES |
Transportation:
Express(DHL, UPS, TNT, JCEX, FEDEX) is available.
Sea and Air transports are available.
The most suitable transport way will be chosen for you.